| Cantidad: | |
|---|---|
Serie S-320
Winston
320W S-320 5V 12V 15V 27V 36V 48V Fuente de alimentación LED Tira de luz
| Modelo | S-320-12 | S-320-15 | S-320-24 | S-320-27 | S-320-36 | S-320-48 | |
| salida | Voltaje DC | 12V | 15V | 24V | 27V | 36V | 48V |
| Tolerancia de voltaje | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
| Corriente nominal | 25A | 20A | 12.5A | 11A | 8.5A | 6.5A | |
| Alcance actual | 0 ~ 25A | 0 ~ 20A | 0 ~ 12.5A | 0 ~ 11A | 0 ~ 8.5A | 0 ~ 6.5A | |
| Potencia nominal | 300W | 300W | 300W | 297W | 306W | 312W | |
| Ondulación y ruido | 100mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | |
| DCvoltage ADJ.range | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
| entrada | Rango de voltaje | 90 ~ 132VAC / 180 ~ 264VAC (seleccionado por interruptor), 255 ~ 373VDC | |||||
| frecuencia | 47 ~ 63HZ | ||||||
| Corriente alterna | 6.0A / 115VAC, 3.5A / 230VAC | ||||||
| eficiencia | 80% | 80% | 82% | 82% | 82% | 83% | |
| Corriente de entrada | Corriente de arranque en frío 25A / 115VAC, 50A / 230VAC | ||||||
| Corriente de fuga | <3.5mA / 240VAC | ||||||
| proteccion | sobrecargar | Potencia de salida nominal: 105% ~ 135% de protección contra sobrecarga de arranque | |||||
| tipo de protección: límite de corriente nominal, recuperación automática después de eliminar la condición de falla | |||||||
| Sobretensión | 15.6 ~ 17.8V | 18.6 ~ 20.8V | 30.6 ~ 33.2V | 33.2 ~ 35.6V | 42.6 ~ 44.2V | 54.8 ~ 56.6V | |
| Tipo de protección: modo hipo, recuperación automática después de eliminar la condición de falla | |||||||
| Exceso de temperatura | ≥55ºCfan encendido, ≤50ºCfan apagado, ≥85ºC inicio protección contra sobretemperatura | ||||||
| Modo de protección: salida de corte, recuperación automática después de que la temperatura se normalice | |||||||
| medio ambiente | Temperatura de trabajo, humedad | -10ºC ~ + 60ºC, 20% ~ 90% HR | |||||
| Temperatura de almacenamiento, humedad | -20ºC ~ + 85ºC, 10% ~ 95% HR sin condensación | ||||||
| Soportar la vibración | 10 ~ 500HZ, 2G 10min / 1cycle, período de 60 minutos, cada eje | ||||||
| la seguridad | Tensión soportada | I / P-O / P: 1.5KVAC I / P-FG: 1.5KVAC O / P-FG: 0.5KVAC | |||||
| Resistencia aislada | I / P-O / P, I / P-FG, O / P-FG: 100M ohmios / 500VDC | ||||||
| Ajuste estándar | Estándar de seguridad | Ajuste UL1012 | |||||
| Estándar de EMC | cumplir con EN55022, CLASSA | ||||||
| otros | Dimensión | 215 * 115 * 50 mm (L * W * H) | |||||
| Peso / embalaje | 1.0kg / 2pcs / 20kg | ||||||
| Nota | 1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25ºC de temperatura ambiente. 2. La ondulación y el ruido se miden a 20 MHz de ancho de banda utilizando un par trenzado de 12 \" | ||||||
Dimensión

Embalaje y envío

320W S-320 5V 12V 15V 27V 36V 48V Fuente de alimentación LED Tira de luz
| Modelo | S-320-12 | S-320-15 | S-320-24 | S-320-27 | S-320-36 | S-320-48 | |
| salida | Voltaje DC | 12V | 15V | 24V | 27V | 36V | 48V |
| Tolerancia de voltaje | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
| Corriente nominal | 25A | 20A | 12.5A | 11A | 8.5A | 6.5A | |
| Alcance actual | 0 ~ 25A | 0 ~ 20A | 0 ~ 12.5A | 0 ~ 11A | 0 ~ 8.5A | 0 ~ 6.5A | |
| Potencia nominal | 300W | 300W | 300W | 297W | 306W | 312W | |
| Ondulación y ruido | 100mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | |
| DCvoltage ADJ.range | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
| entrada | Rango de voltaje | 90 ~ 132VAC / 180 ~ 264VAC (seleccionado por interruptor), 255 ~ 373VDC | |||||
| frecuencia | 47 ~ 63HZ | ||||||
| Corriente alterna | 6.0A / 115VAC, 3.5A / 230VAC | ||||||
| eficiencia | 80% | 80% | 82% | 82% | 82% | 83% | |
| Corriente de entrada | Corriente de arranque en frío 25A / 115VAC, 50A / 230VAC | ||||||
| Corriente de fuga | <3.5mA / 240VAC | ||||||
| proteccion | sobrecargar | Potencia de salida nominal: 105% ~ 135% de protección contra sobrecarga de arranque | |||||
| tipo de protección: límite de corriente nominal, recuperación automática después de eliminar la condición de falla | |||||||
| Sobretensión | 15.6 ~ 17.8V | 18.6 ~ 20.8V | 30.6 ~ 33.2V | 33.2 ~ 35.6V | 42.6 ~ 44.2V | 54.8 ~ 56.6V | |
| Tipo de protección: modo hipo, recuperación automática después de eliminar la condición de falla | |||||||
| Exceso de temperatura | ≥55ºCfan encendido, ≤50ºCfan apagado, ≥85ºC inicio protección contra sobretemperatura | ||||||
| Modo de protección: salida de corte, recuperación automática después de que la temperatura se normalice | |||||||
| medio ambiente | Temperatura de trabajo, humedad | -10ºC ~ + 60ºC, 20% ~ 90% HR | |||||
| Temperatura de almacenamiento, humedad | -20ºC ~ + 85ºC, 10% ~ 95% HR sin condensación | ||||||
| Soportar la vibración | 10 ~ 500HZ, 2G 10min / 1cycle, período de 60 minutos, cada eje | ||||||
| la seguridad | Tensión soportada | I / P-O / P: 1.5KVAC I / P-FG: 1.5KVAC O / P-FG: 0.5KVAC | |||||
| Resistencia aislada | I / P-O / P, I / P-FG, O / P-FG: 100M ohmios / 500VDC | ||||||
| Ajuste estándar | Estándar de seguridad | Ajuste UL1012 | |||||
| Estándar de EMC | cumplir con EN55022, CLASSA | ||||||
| otros | Dimensión | 215 * 115 * 50 mm (L * W * H) | |||||
| Peso / embalaje | 1.0kg / 2pcs / 20kg | ||||||
| Nota | 1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25ºC de temperatura ambiente. 2. La ondulación y el ruido se miden a 20 MHz de ancho de banda utilizando un par trenzado de 12 \" | ||||||
Dimensión

Embalaje y envío