Cantidad: | |
---|---|
Serie S-200
Winston
Fuente de alimentación de modo de interruptor S-200 de interior de 200 W ordinaria
MODEL | S-200-5 | S-200-12 | S-200-15 | S-200-24 | S-200-36 | S-200-48 |
Voltaje DC | 5V | 12V | 15V | 24V | 36V | 48V |
ALCANCE ACTUAL | 0 ~ 40A | 0 ~ 16.5A | 0 ~ 13.3A | 0 ~ 8.5A | 0 ~ 5.5A | 0 ~ 4.2A |
EFICIENCIA | 79% | 82% | 83% | 83% | 86% | 86% |
ONDA Y RUIDO | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | 200mVp-p | 200mVp-p |
GAMA AJUSTABLE PARA VOLTAJE DC | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% |
REGULACIÓN DE LÍNEA | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
REGULACIÓN DE CARGA | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
CONFIGURACIÓN, AUMENTO DEL TIEMPO DE ESPERA | 200 ms, 50 ms, 20 ms / 230 VCA a plena carga | |||||
RANGO DE VOLTAJE | 90 ~ 132VAC / 180-264VAC por interruptor 254 ~ 370VDC | |||||
RANGO DE FRECUENCIA | 47 ~ 63Hz | |||||
CORRIENTE DE IMPACTO | Corriente de arranque en frío 30A / 115VAC 60A / 230VAC | |||||
TEMPERATURA DE TRABAJO. | -10 ~ + 50ºC | |||||
PROTECCIÓN DE SOBRECARGA | 105% -150% cortó la salida, recuperación automática | |||||
PROTECCION AL SOBREVOLTAJE | 105% -150% shunt down O / P voltaje, vuelva a encender para recuperar | |||||
TENSIÓN SOPORTADA | I / P-O / P: 1.5KV I / P-FG: 1.5KV O / P-FG: 0.5KV 1 minuto | |||||
RESISTENCIA DE AISLAMIENTO | I / P-O / P, I / P-FG, O / P-FG: 500VDC / 100M Ohmios | |||||
DIMENSIÓN | 199 * 110 * 50 mm (L * W * H) | |||||
PESO | 0.9kg | |||||
EMBALAJE | 42 * 31.5 * 26cm / 20pcs / 18Kg | |||||
1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25 ° C de temperatura ambiente. 2. La ondulación y el ruido se miden a 20MHz de ancho de banda utilizando un cable de par trenzado de 12 \"terminado con un condensador paralelo de 0.1uf y 47uf. 3. Tolerancia: incluye tolerancia de configuración, regulación de línea y regulación de carga. 4. La regulación de la línea se mide desde la línea baja a la línea alta a la carga nominal. 5. La regulación de carga se mide de 0% a 100% de carga nominal. 6. La fuente de alimentación se considera un componente que se instalará en un equipo final. El equipo final debe volver a confirmarse que aún cumple con EMC |
Dimensión
Fuente de alimentación de modo de interruptor S-200 de interior de 200 W ordinaria
MODEL | S-200-5 | S-200-12 | S-200-15 | S-200-24 | S-200-36 | S-200-48 |
Voltaje DC | 5V | 12V | 15V | 24V | 36V | 48V |
ALCANCE ACTUAL | 0 ~ 40A | 0 ~ 16.5A | 0 ~ 13.3A | 0 ~ 8.5A | 0 ~ 5.5A | 0 ~ 4.2A |
EFICIENCIA | 79% | 82% | 83% | 83% | 86% | 86% |
ONDA Y RUIDO | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | 200mVp-p | 200mVp-p |
GAMA AJUSTABLE PARA VOLTAJE DC | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% |
REGULACIÓN DE LÍNEA | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
REGULACIÓN DE CARGA | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
CONFIGURACIÓN, AUMENTO DEL TIEMPO DE ESPERA | 200 ms, 50 ms, 20 ms / 230 VCA a plena carga | |||||
RANGO DE VOLTAJE | 90 ~ 132VAC / 180-264VAC por interruptor 254 ~ 370VDC | |||||
RANGO DE FRECUENCIA | 47 ~ 63Hz | |||||
CORRIENTE DE IMPACTO | Corriente de arranque en frío 30A / 115VAC 60A / 230VAC | |||||
TEMPERATURA DE TRABAJO. | -10 ~ + 50ºC | |||||
PROTECCIÓN DE SOBRECARGA | 105% -150% cortó la salida, recuperación automática | |||||
PROTECCION AL SOBREVOLTAJE | 105% -150% shunt down O / P voltaje, vuelva a encender para recuperar | |||||
TENSIÓN SOPORTADA | I / P-O / P: 1.5KV I / P-FG: 1.5KV O / P-FG: 0.5KV 1 minuto | |||||
RESISTENCIA DE AISLAMIENTO | I / P-O / P, I / P-FG, O / P-FG: 500VDC / 100M Ohmios | |||||
DIMENSIÓN | 199 * 110 * 50 mm (L * W * H) | |||||
PESO | 0.9kg | |||||
EMBALAJE | 42 * 31.5 * 26cm / 20pcs / 18Kg | |||||
1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25 ° C de temperatura ambiente. 2. La ondulación y el ruido se miden a 20MHz de ancho de banda utilizando un cable de par trenzado de 12 \"terminado con un condensador paralelo de 0.1uf y 47uf. 3. Tolerancia: incluye tolerancia de configuración, regulación de línea y regulación de carga. 4. La regulación de la línea se mide desde la línea baja a la línea alta a la carga nominal. 5. La regulación de carga se mide de 0% a 100% de carga nominal. 6. La fuente de alimentación se considera un componente que se instalará en un equipo final. El equipo final debe volver a confirmarse que aún cumple con EMC |
Dimensión