Cantidad: | |
---|---|
SP-320
Winston
8504401990
SP-320
Winston
Hecho en China
Caja de cartón estándar de exportación
PCS
10
3-7days
Modelo | SP-320-3.3 | SP-320-5 | SP-320-7.5 | SP-320-12 | SP-320-13.5 | SP-320-15 | SP-320-24 | SP-320-27 | SP-320-36 | SP-320-48 | |
Salida | Voltaje DC | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 36V | 48V |
Tolerancia de voltaje | ± 1% | ± 2% | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Corriente nominal | 60A | 55A | 40A | 25A | 22A | 20A | 13A | 11.7A | 8.8A | 6.7A | |
Alcance actual | 0-60A | 0-55A | 0-40A | 0-25A | 0-22A | 0-20A | 0-13A | 0-11.7A | 0-8.8A | 0-6.7A | |
Potencia nominal | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | |
Ondulación y ruido | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 220mvp-p | 240mvp-p | |
DCvoltage ADJ.range | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
Entrada | Rango de voltaje | 90 ~ 264VAC, 120 ~ 373VDC | |||||||||
frecuencia | 47 ~ 63HZ | ||||||||||
Corriente alterna | 1.6A / 115VAC, 0.8A / 230VAC | ||||||||||
eficiencia | sesenta y cinco% | 71% | 76% | 79% | 80% | 81% | 83% | 83% | 84% | ||
Corriente de entrada | Corriente de arranque en frío 20A / 115VAC, 40A / 230VAC | ||||||||||
Corriente de fuga | <3.5mA / 240VAC | ||||||||||
Proteccion | sobrecargar | Potencia de salida nominal: 115% ~ 150% de protección contra sobrecarga de arranque | |||||||||
Tipo de protección: salida de corte, recuperación automática después de eliminar la condición de falla | |||||||||||
Tipo de protección: modo hipo, recuperación automática después de eliminar la condición de falla | |||||||||||
Medio ambiente | Temperatura de trabajo, humedad | -10 ℃ ~ + 60 ℃ , 20% ~ 90% HR | |||||||||
Temperatura de almacenamiento, humedad | -20 ℃ ~ + 85 ℃ , 10% ~ 95% HR sin condensación | ||||||||||
Soportar la vibración | 10 ~ 500HZ, 2G 10min / 1cycle, período de 60 minutos, cada eje | ||||||||||
La seguridad | Tensión soportada | I / P-O / P: 1.5KVAC I / P-FG: 1.5KVAC O / P-FG: 0.5KVAC | |||||||||
Resistencia aislada | I / P-O / P, I / P-FG, O / P-FG: 100M ohmios / 500VDC | ||||||||||
Ajuste estándar | Estándar de seguridad | Ajuste UL1012 | |||||||||
Estándar de EMC | EN55022, CLASSA | ||||||||||
Otros | Dimensión | 210 * 115 * 50 mm (L * W * H) | |||||||||
Nota | 1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25 ° C de temperatura ambiente. | ||||||||||
2. La ondulación y el ruido se miden a 20MHz de ancho de banda utilizando un cable de par trenzado de 12 \"terminado con un condensador paralelo de 0.1uf y 47uf. | |||||||||||
3. Tolerancia: incluye tolerancia de configuración, regulación de línea y regulación de carga. |
Modelo | SP-320-3.3 | SP-320-5 | SP-320-7.5 | SP-320-12 | SP-320-13.5 | SP-320-15 | SP-320-24 | SP-320-27 | SP-320-36 | SP-320-48 | |
Salida | Voltaje DC | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 36V | 48V |
Tolerancia de voltaje | ± 1% | ± 2% | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
Corriente nominal | 60A | 55A | 40A | 25A | 22A | 20A | 13A | 11.7A | 8.8A | 6.7A | |
Alcance actual | 0-60A | 0-55A | 0-40A | 0-25A | 0-22A | 0-20A | 0-13A | 0-11.7A | 0-8.8A | 0-6.7A | |
Potencia nominal | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | 320W | |
Ondulación y ruido | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 220mvp-p | 240mvp-p | |
DCvoltage ADJ.range | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | -9% ~ + 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
Entrada | Rango de voltaje | 90 ~ 264VAC, 120 ~ 373VDC | |||||||||
frecuencia | 47 ~ 63HZ | ||||||||||
Corriente alterna | 1.6A / 115VAC, 0.8A / 230VAC | ||||||||||
eficiencia | sesenta y cinco% | 71% | 76% | 79% | 80% | 81% | 83% | 83% | 84% | ||
Corriente de entrada | Corriente de arranque en frío 20A / 115VAC, 40A / 230VAC | ||||||||||
Corriente de fuga | <3.5mA / 240VAC | ||||||||||
Proteccion | sobrecargar | Potencia de salida nominal: 115% ~ 150% de protección contra sobrecarga de arranque | |||||||||
Tipo de protección: salida de corte, recuperación automática después de eliminar la condición de falla | |||||||||||
Tipo de protección: modo hipo, recuperación automática después de eliminar la condición de falla | |||||||||||
Medio ambiente | Temperatura de trabajo, humedad | -10 ℃ ~ + 60 ℃ , 20% ~ 90% HR | |||||||||
Temperatura de almacenamiento, humedad | -20 ℃ ~ + 85 ℃ , 10% ~ 95% HR sin condensación | ||||||||||
Soportar la vibración | 10 ~ 500HZ, 2G 10min / 1cycle, período de 60 minutos, cada eje | ||||||||||
La seguridad | Tensión soportada | I / P-O / P: 1.5KVAC I / P-FG: 1.5KVAC O / P-FG: 0.5KVAC | |||||||||
Resistencia aislada | I / P-O / P, I / P-FG, O / P-FG: 100M ohmios / 500VDC | ||||||||||
Ajuste estándar | Estándar de seguridad | Ajuste UL1012 | |||||||||
Estándar de EMC | EN55022, CLASSA | ||||||||||
Otros | Dimensión | 210 * 115 * 50 mm (L * W * H) | |||||||||
Nota | 1. Todos los parámetros NO mencionados especialmente se miden a una entrada de 230 VCA, carga nominal y 25 ° C de temperatura ambiente. | ||||||||||
2. La ondulación y el ruido se miden a 20MHz de ancho de banda utilizando un cable de par trenzado de 12 \"terminado con un condensador paralelo de 0.1uf y 47uf. | |||||||||||
3. Tolerancia: incluye tolerancia de configuración, regulación de línea y regulación de carga. |